Поиск инструкции

9% PORCELAIN ETCHANT

Инструкция по применению

Применяется в условиях стоматологической клиники подробнее здесь.

PORCELAIN ETCHANT

9.5% Buffered Hydrofluoric Acid Gel
GENERAL INFORMATION
PORCELAIN ETCHANT is a 9.5% buffered hydrofluoric acid gel that must be handled
with extreme care (See WARNINGS). BISCO'S 9.5% PORCELAIN ETCHANT has
been buffered, gelled and packaged to minimize problems, provided that it is used in
accordance with these instructions.
PORCELAIN ETCHANT improves the mechanical bond between porcelain and
adhesive/cement by increasing the surface area of the porcelain. The effect is similar to
sandblasting but is more controlled and effective.
Indications for Use:
The principle use of 9.5% PORCELAIN ETCHANT is for etching porcelain prior to:
1. Cementation of porcelain restorations.
2. Repair of porcelain restorations.
Warnings:
• Do not use this product until you have thoroughly read and understood these
instructions.
• Hydrofluoric acid is a very powerful and aggressive chemical. It is a severe eye
and tissue irritant. If accidentally splashed into the eye, flush with copious
amounts of water for 15 minutes and seek immediate medical attention.
Hydrofluoric acid also releases a vapor that irritates respiratory passageways.
Chronic inhalation of fumes is dangerous and can cause damage. Extreme care
must be taken to protect the patient, operator and assistant. These individuals
must wear protective eyewear. The operator and assistant must wear protective
gloves. Rubber dam isolation must be used for intraoral porcelain repair.
• DO NOT use PORCELAIN ETCHANT to etch exposed enamel or dentin surfaces.
• Injury may result if PORCELAIN ETCHANT is allowed to remain on the skin or
mucosa for extended periods of time. Contact with other tissues: rinse spills
immediately with a copious amount of water for several minutes.
• Verify flow of etchants prior to applying intraorally. If resistance is met, replace tip
and re-check. Use only recommended tips.
• Do not allow any product to be ingested.
• Re-cap syringes with the luer lock cap. Disinfect and wipe syringe with an
intermediate level disinfectant between uses.
Cautions:
• Cross-contamination: Product may contain items that are designed for one time
use. Dispose of used or contaminated unit-dose components and accessories.
Do not clean, disinfect or reuse.
Precautions:
• Do not re-etch restorations that have been etched by the lab. Over etching
porcelain may cause weakening of porcelain or degradation of bond strength.
• PORCELAIN ETCHANT will microscopically roughen porcelain and glass
surfaces. As such, care must be taken to avoid having the etchant contact glazed
porcelain surfaces since these surfaces will lose their gloss.• Refer to product MSDS for additional risk and safety information.
• Refer to individual component labels for specific expiration dates.
• Not all ceramic systems are etchable. Contact your lab for manufacturer's
instructions.
INSTRUCTIONS FOR USE
1. ETCHING PORCELAIN RESTORATIONS PRIOR TO CEMENTATION
1. Protective eyewear and gloves must be worn by operator and assistant.
2. If the lab has not already etched the restoration, remove cap from PORCELAIN
ETCHANT, securely attach dispensing tip and verify etchant flow prior to
application. Apply PORCELAIN ETCHANT (9.5% HF) to the dry porcelain
surface for 90 seconds. Care must be taken to avoid having the etchant contact
glazed porcelain surfaces since these surfaces will lose their gloss.
3. Rinse with a copious amount of water and air dry. The etched surface should
appear dull and frosty (if porcelain has a white/chalky appearance, agitate a moist
microbrush on the porcelain to remove salt and debris created by etching).
4. Apply one to two thin coats of silane with a brush to the etched internal surface
of the restoration according to manufacturer instructions. Dry with air syringe.
5. Proceed with adhesive applications and cementation according to the
manufacturer's instructions.
2. REPAIR OF PORCELAIN RESTORATIONS
1. Protective eyewear must be worn by patient, operator and assistant. Protective
gloves must be worn by operator and assistant.
2. Remove the glaze & bevel (45 degree) the porcelain around the area to be
repaired. (Remove any old composite remaining from previous repairs.)
3. Isolate the area to be etched with a rubber dam. BISCO'S BARRIER GEL* should
be placed where etching is not desired.
4. Remove cap from PORCELAIN ETCHANT, securely attach dispensing tip and
verify etchant flow prior to applying intraorally. Apply PORCELAIN ETCHANT
(9.5% HF) to the dry porcelain surface for 90 seconds. Continue to observe the
etch site throughout the entire procedure. Suction the PORCELAIN ETCHANT,
then rinse with a copious amount of water and air dry. The etched surface should
appear dull and frosty (if porcelain has a white/chalky appearance, agitate a moist
microbrush on the porcelain to remove salt and debris created by etching, rinse
and dry).
5. Apply one to two thin coats of silane with a brush to the etched surface of the
restoration and allow to dwell for 30 seconds. Dry with air syringe.
6. Apply an adhesive system according to the manufacturer's instructions.
Complete the repair with composite and finish/polish.
NOTE: For repairs with exposed Metal, Alumina, Zirconia or Composite,
see the instructions for BISCO's INTRAORAL REPAIR KIT*
* BARRIER GEL and INTRAORAL REPAIR KIT are manufactured by BISCO, Inc.STORAGE: Store at room temperature (20°C/68°F - 25°C/72°F).
WARRANTY: BISCO, Inc. recognizes its responsibility to replace products if proven
defective. BISCO, Inc. does not accept liability for any damages or loss, either direct or
consequential, stemming from the use of or inability to use the products as described.
Before using, it is the responsibility of the user to determine the suitability of the product

for its intended use. The user assumes all risk and liability in connection therewith. 

 